Property | Test Method | Result |
Nominal Thickness (in)4 | 1/2, 3/4, 1, 1 1/2, 2, 2 1/2, 3, 4 | |
Nominal Board Width (ft)4 Nominal Board Length (ft)4 |
2 / 4 8 |
|
Edge Profile4 | Square or Shiplap | |
Property Type | ASTM C 578 | IV |
Compressive Strength, Min. (psi@ 10% deflection) |
ASTM D 1621 | 25 |
Water Absorption, Max. (% by volume) |
ASTM C 272 | 0.1 |
Density, Min. (lb/ft³) |
ASTM C 303 | 1.6 |
Water Vapor Permeance, Max.² (perm) |
ASTM E 96 (Dessicant Method) |
1.5 |
Service Temperature, Max (°F) | 165 | |
Thermal | ||
Thermal Resistance, R-value1
(°F.ft².hr / Btu per in thick) |
ASTM C 518 (@75°F Mean Temperature) |
5.0 |
Thermal Conductivity, k-value (Btu.in / hr.ft².ºF) |
ASTM C 518 (@75°F Mean Temperature) |
0.2 |
Fire & Smoke | ||
Flame Spread³ Smoke Developed³ |
ASTM E 84 / UL723 | 15 (Class A) 140 |
1 Specimens are aged and tested in accordance with FTC Rule (16 CFR, Part 460) and ASTM C578.
2 Permeance shown is for 1” thick board. Permeance typically decreases as board thickness increases.
3 These numerical flame spread and smoke developed ratings are not intended to reflect hazards presented by this material under actual fire conditions. All applicable building codes must be followed.
4 Not all combinations of thickness, length, width and edge profile are available.